EXTERIOR LIGHTING:TURN SIGNAL:FLASHER UNIT
NHTSA #18V418000Reported June 20, 2018 · Gillig LLC
Potentially affected: 25,579 vehicles
Defect description
Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Safety consequence
The reduced visibility of the turn signals can increase the risk of a crash.
Manufacturer remedy
Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
EXTERIOR LIGHTING:TURN SIGNAL
NHTSA #17V119000Reported February 24, 2017 · Gillig LLC
Potentially affected: 17,056 vehicles
Defect description
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
Safety consequence
The reduced visibility of the turn signals may increase the risk of a crash.
Manufacturer remedy
Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
SEATS
NHTSA #16V011000Reported January 13, 2016 · Gillig LLC
Potentially affected: 6,734 vehicles
Defect description
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.
Safety consequence
If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.
Manufacturer remedy
Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
ELECTRICAL SYSTEM:WIRING:FRONT UNDERHOOD
NHTSA #15V420000Reported July 1, 2015 · Gillig LLC
Potentially affected: 6,971 vehicles
Defect description
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.
Safety consequence
If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.
Manufacturer remedy
Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners may contact Gillig customer service at 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
ENGINE AND ENGINE COOLING:ENGINE
NHTSA #15V262000Reported May 5, 2015 · Gillig LLC
Potentially affected: 1,101 vehicles
Defect description
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.
Safety consequence
If engine oil comes into contact with a hot surface, there is an increased risk of a fire.
Manufacturer remedy
Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 2, 2015. Owners may contact Gillig customer service at 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
ENGINE AND ENGINE COOLING:ENGINE
NHTSA #14V358000Reported June 23, 2014 · Gillig LLC
Potentially affected: 648 vehicles
Defect description
Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Safety consequence
If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Manufacturer remedy
Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
ENGINE AND ENGINE COOLING:ENGINE
NHTSA #14V084000Reported February 27, 2014 · Gillig LLC
Potentially affected: 643 vehicles
Defect description
Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.
Safety consequence
The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.
Manufacturer remedy
Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1-510-785-1500 or Cummins Inc. at 1-800-343-7357.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
VISIBILITY:GLASS, SIDE/REAR
NHTSA #12V506000Reported October 18, 2012 · GILLIG CORPORATION
Potentially affected: 657 vehicles
Defect description
Gillig is recalling certain model year 2010 Lowfloor transit buses, manufactured April 16, 2010, through November 16, 2010, and equipped with Ricon 3-Minute Urban Transit Bus Window sets. The composition of the material used to cast the handle that opens the egress window is incorrect, resulting in a reduction in material strength. The handle(s) on the emergency egress passenger windows may break before the window latch is released.
Safety consequence
In the event the egress window handle fails during an actual emergency situation, passengers may be trapped in the vehicle placing them at risk of injury.
Manufacturer remedy
Gillig will notify owners, and dealers will replace the window handles free of charge. The recall began during October 2012. Owners may contact Gillig at 1-800-735-1500 for more information.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
ENGINE AND ENGINE COOLING
NHTSA #11V411000Reported August 10, 2011 · GILLIG CORPORATION
Potentially affected: 563 vehicles
Defect description
GILLIG IS RECALLING CERTAIN MODEL YEAR 2010-2011 LOWFLOOR BUSES EQUIPPED WITH CUMMINS ENGINES. THE V-BAND CLAMP ASSEMBLY USED TO CONNECT THE INLET AND OUTLET CONE SECTIONS TO THE DIESEL OXIDATION CATALYST (DOC) DIESEL PARTICULATE FILTER (DPF) INCLUDE A T-BOLT WHICH CAN FRACTURE AND FAIL WHEN SUBJECTED TO STRESS OR LOAD. A FRACTURE OR FAILURE OF THE T-BOLT MAY CAUSE THE CLAMP TO LOOSEN AND THE INLET OR OUTLET SECTIONS ATTACHED TO THE DOC/DPF HOUSING TO DISCONNECT.
Safety consequence
IF THE INLET OR OUTLET SECTIONS DISCONNECT, HOT EXHAUST GASES CAN VENT PRIOR TO EXITING THE TAILPIPE, CREATING THE RISK OF COMBUSTION AND A FIRE. IF BOTH CLAMPS FAIL, THERE IS A RISK IN SOME APPLICATIONS THAT THE DOC/DPF HOUSING MAY DETACH COMPLETELY, CREATING A ROAD HAZARD.
Manufacturer remedy
GILLIG IS WORKING WITH CUMMINS TO IDENTIFY OWNERS. CUMMINS IS HANDLING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN PLEASE SEE NHTSA RECALL 11E-031. OWNERS MAY CONTACT CUMMINS AT 1-812-377-5000.
Notes
OWNERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO <A HREF=HTTP://WWW.SAFERCAR.GOV>HTTP://WWW.SAFERCAR.GOV</A> .
Other Gillig Low Floor model years
Check your 2010 Gillig Low Floor VIN
Not every recall applies to every VIN in a given year. Enter the 17-character VIN from your Gillig Low Floor at nhtsa.gov/recalls to see whether your specific vehicle has an unrepaired recall.
Check a Gillig VIN