NHTSA Office of Defects Investigation

Preliminary Evaluation PE13-014: Alleged Loss of Steering

  • Closed

NHTSA's Office of Defects Investigation opened Preliminary Evaluation PE13-014 on May 7, 2013 and closed it on January 31, 2014. NHTSA's investigations file lists 5 Ford models for it.

Updated daily from NHTSA's investigations file

Key facts

NHTSA number
PE13-014 (also written PE13014)
Investigation type
Preliminary Evaluation The first stage of most defect investigations: NHTSA's Office of Defects Investigation gathers basic information about a possible safety defect, including from the manufacturer.
Status
Closed January 31, 2014
Opened
Closed
Vehicle or equipment manufacturer
Ford Motor Company
Components
Steering; Steering — Gear Box (OTHER THAN RACK AND PINION)
Vehicles and equipment
5 Ford models, including the F-250 and F-250 SD

A recall appears here only when NHTSA's investigations file links one to the investigation; NHTSA's summary or record can name others.

NHTSA's summary

As NHTSA's Office of Defects Investigation wrote it for Preliminary Evaluation PE13-014.

The Office of DefectsInvestigation (ODI) opened PE13-014 after identifying five complaints alleging steering gear failure in model year (MY) 2008 Ford F-250 and F-350 Super Duty pick-up trucks and to evaluate the relationship between the design history of the steering gear assembly and the alleged defect.

As background, ODI investigated steering gear sector shaft fractures in approximately 1.3 million MY 1999 - 2001 Ford Super Duty pick-up trucks and MY 2000 - 2001 Ford Excursion sport utility vehicles in Engineering Analysis EA01-009.

The investigation determined that the sector shaft failures were the result of extraordinary, possibly multiple, impacts and not the result of fatigue.

No defect in design, manufacturing or materials was identified in the sector shaft.

EA01-009 was closed August 19, 2003 with 169 complaints, resulting in a rate of 12.9 incidents per 100,000 vehicles after approximately one year of service.

Ford increased the diameter of the sector shaft from 1.375 inches to 1.625 inches at the start of MY 2005 production, increasing the resistance of the steering gear assembly to torsional overload by approximately 48% and changing the failure mode from sector shaft fracture to cracked or broken sector shaft gear teeth.

The redesigned steering gear assembly was used in approximately 1.1 million MY 2005 through 2009 Ford Super Duty pick-up trucks, including the subject vehicles.

Figure 1 shows the basic steering system design used in Ford Super Duty trucks investigated in EA01-009 and PE13-014. Figure 2 shows the locations of failures resulting from impact related torsional overloading of the sector shaft for the subject vehicles and the prior generation Ford Super Duty trucks investigated in EA01-009.

Figure 3 shows an example of a failed sector shaft investigated in EA01-009 and comparisons of fracture surfaces of sector shafts failing from fatigue loading and from torsional overload.

Ford provided field return part analysis of failed steering gears from MY 2005 through 2009 Super Duty trucks found evidence of broken sector shaft gear teeth and piston damage consistent with incidents of single event overload (Figure 4).

Laboratory analysis found no evidence of fatigue or material property defects in any of the fractures.

Analysis of complaint rates by vehicle build month showed no patterns indicating potential manufacturing quality issues and no difference before and after Ford introduced design changes to the input shaft and sector shaft seals in July 2007 to address potential leak concerns (Figure 5).

Analysis of failures by time in service indicates a random failure pattern/distribution, consistent with incidents of impact induced overload (Figure 6). The complaint rate for the subject vehicles after approximately 5 to 6 years, 7.1 incidents per 100,000 vehicles, is lower than the rate observed in EA01-009. Furthermore, similar to the condition investigated in EA01-009, a number of incident records include evidence of impact loads (e.g., curb strikes) and several alleged crashes include incidents in which information suggests that the steering gear failure was most likely a result of crash forces, rather than the cause of the crash.

A safety-related defect has not been identified at this time and further use of agency resources does not appear to be warranted.

Accordingly, this investigation is closed.

The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist.

The agency will monitor this issue and reserves the right to take further action if warranted by the circumstances.

The ODI complaints cited above can be reviewed at ww

Vehicles and equipment listed for this investigation

NHTSA's investigations file lists these vehicles and equipment for Preliminary Evaluation PE13-014. A listed model year means only that an investigation names it; it says nothing about any particular vehicle. Model years with a try.vin recall page link to that page's NHTSA investigations section.

Ford

All Ford recalls

What an NHTSA investigation is

NHTSA's Office of Defects Investigation (ODI) looks into possible safety defects in vehicles and equipment, often after owner complaints. An investigation usually starts as a Preliminary Evaluation, or as a Recall Query when it concerns whether an existing recall covers the right vehicles or fixes the problem, and ODI can upgrade it to a more detailed Engineering Analysis. A Defect Petition asks NHTSA to open an investigation, and Audit and Equipment Queries are administrative investigations into whether companies complied with federal vehicle safety requirements, such as reporting, recall and certification rules.

An open investigation is not a finding that a safety defect exists, and NHTSA can close one without a recall.

To see whether a specific vehicle has an open recall, enter its VIN at nhtsa.gov/recalls.

Ford VIN check: decode a VIN to see its year, make and model.

Sources

NHTSA's investigation record for PE13-014

Investigation details come from NHTSA's investigations file, which try.vin imports once a day. The investigation types are described from the U.S. Department of Transportation Inspector General's May 2023 report on NHTSA's Office of Defects Investigation, NHTSA's petition rules (49 CFR Parts 552 and 557) and NHTSA's Office of Defects Investigation procedures. How try.vin reads NHTSA investigations.