NHTSA vehicle safety data
2003 Fleetwood Revolution Recalls & Complaints
The 2003 Fleetwood Revolution has 4 NHTSA recall campaigns and 3 owner complaints on file as of November 3, 2026. Recall repairs are usually free at an authorized Fleetwood dealer.
NHTSA recall and complaint data for the 2003 Fleetwood Revolution. Recall data is refreshed daily from NHTSA.
2003 Fleetwood Revolution owner complaints
Owners have filed 3 complaints with NHTSA about the 2003 Fleetwood Revolution, describing incidents dated December 19, 2002 to June 26, 2009.
Most-cited components
- Electrical System 1 complaint
- Equipment 1 complaint
- Structure 1 complaint
- Unknown or Other 1 complaint
Newest complaints
ODI #11121307 · Filed
TL* THE CONTACT OWNS A 2003 FLEETWOOD REVOLUTION EQUIPPED WITH A NORCOLD REFRIGERATOR, MODEL NUMBER: 1200LRIM. THE CONTACT STATED THAT THE REFRIGERATOR EXHIBITED THE SAME SYMPTOMS AS LISTED IN NHTSA CAMPAIGN NUMBER: 07V120000 (EQUIPMENT). THE RV WAS TAKEN TO AN UNKNOWN DEALER IN JUNO BEACH, FL TO BE…
ODI #10050281 · Filed
THE ALUMINUM RIVETS THAT HOLD THE ROOF RAILS ARE STRETCHING. AS A RESULT, WATER RUNS DOWN THE WALLS AND INTO THE COACH. THIS COULD RESULT IN MILDEW OR MOLD DEVELOPING ON THE WALL, WHICH COULD MAKE THE OCCUPANTS SICK. DEALERSHIP IS PROVIDING NO ASSISTANCE. THERE IS A MANUFACTURER'S PRODUCT UPGRADE…
ODI #10001722 · Filed
CONSUMER STATED THAT WHEN VEHICLE IS TURNED OFF THEY COULD STILL HEAR THE IGNITION RUNNING. DEALER NOTIFIED.
NHTSA defect investigations
NHTSA's investigations file lists the 2003 Fleetwood Revolution in 1 investigation. A listed model year means only that an investigation names it; it says nothing about any particular vehicle. An open investigation is not a finding that a safety defect exists, and NHTSA can close one without a recall.
Open and recently closed NHTSA defect investigationsREFRIGERATOR FIRE/NORCOLD
NHTSA #09V312000 · Equipment · NHTSA notice
Reported July 28, 2009 · FLEETWOOD RV, INC.
Potentially affected: 6,684 vehicles
Owners notified June 26, 2009 · Vehicles built August 1, 2001 – February 3, 2003 (per NHTSA)
Defect description
FLEETWOOD RV IS RECALLING CERTAIN MODEL YEAR 2005 AND 2006 MOTORHOMES MANUFACTURED BETWEEN JULY 24, 2004 AND MARCH 11, 2005, EQUIPPED WITH NORCOLD MODEL 1200LR, 1200LRIM, AND 1201LRIM REFRIGERATORS WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK. IF A LEAK OCCURS AND THE REFRIGERATOR CONTINUES TO BE OPERATED AFTER SOLUTION CIRCULATION HAS CEASED THE HEAT SOURCE COULD GENERATE VERY HIGH TEMPERATURES. AT SUCH HIGH TEMPERATURES, THE COOLING UNIT COULD RUPTURE.
Safety consequence
IF A LEAK OCCURS AND THE UNIT IS CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.
Manufacturer remedy
FLEETWOOD RV WILL NOTIFY OWNERS AND THE VEHICLE'S REFRIGERATOR WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL IS EXPECTED TO BEGIN DURING SEPTEMBER 2009. OWNERS MAY CONTACT FLEETWOOD RV AT 1-800-509-3418 OR NORCOLD'S RECALL CENTER AT 1-800-767-9101.
Notes
OWNERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO <A HREF=HTTP://WWW.SAFERCAR.GOV>HTTP://WWW.SAFERCAR.GOV</A> .
REFRIGERATOR/DOMETIC
NHTSA #08V320000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice
Reported July 15, 2008 · FLEETWOOD ENTERPRISES, INC.
Potentially affected: 70,101 vehicles
Owners notified October 24, 2008 · Vehicles built April 1, 2003 – November 30, 2006 (per NHTSA) · Recall influenced by NHTSA's Office of Defects Investigation
Defect description
FLEETWOOD IS RECALLING 70,101 MY 2003-2007 SOUTHWIND, PACE ARROW, BOUNDER, FLAIR, STORM, FIESTA, TERRA GAS CLASS A MOTOR HOMES; BOUNDER, DISCOVERY, PROVIDENCE, EXCURSION, EXPEDITION, REVOLUTION, AMERICAN EAGLE, AMERICAN HERITAGE, AMERICAN TRADITION DIESEL CLASS A MOTOR HOMES; JAMBOREE TIOGA CLASS C MOTOR HOMES; AND PROWLER, WILDERNESS, TERRY, MALLARD, PIONEER, PRIDE AND TRIUMPH CONVENTIONAL AND FIFTH WHEEL TRAVEL TRAILERS EQUIPPED WITH A TWO-DOOR REFRIGERATORS MANUFACTURED BY THE DOMETIC CORPORATION. THE REFRIGERATOR MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Safety consequence
IF THIS SOLUTION IS EXPOSED TO AN IGNITION SOURCE UNDER CERTAIN SPECIFIC CIRCUMSTANCES, IT CAN RESULT IN A VEHICLE FIRE.
Manufacturer remedy
FLEETWOOD IS WORKING WITH DOMETIC TO REPAIR THESE REFRIGERATORS (PLEASE SEE 08E032). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST THE OWNER IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR FLEETWOOD AT 1-800-322-8216.
Notes
CUSTOMERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO HTTP://WWW.SAFERCAR.GOV.
REFRIGERATOR/DOMETIC
NHTSA #07V120000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice
Reported March 19, 2007 · FLEETWOOD ENTERPRISES, INC.
Potentially affected: 167,096 vehicles
Owners notified May 10, 2007 · Vehicles built April 1, 1997 – July 31, 2003 (per NHTSA)
Defect description
CERTAIN MOTOR HOMES AND TRAVEL TRAILERS EQUIPPED WITH A TWO-DOOR REFRIGERATOR, MANUFACTURED BY THE DOMETIC CORPORATION, MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Safety consequence
RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Manufacturer remedy
FLEETWOOD WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST YOU IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR FLEETWOOD AT 1-800-322-8216.
Notes
CUSTOMERS MAY CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY: 1-800-424-9153); OR GO TO HTTP://WWW.SAFERCAR.GOV.
FLEETWOOD/DOOR ENTRY ELECTRIC POWER
NHTSA #03V304000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice
Reported August 20, 2003 · FLEETWOOD ENTERPRISES, INC.
Potentially affected: 1,273 vehicles
Fleetwood campaign 30815 · Owners notified September 10, 2003 · Vehicles built August 1, 2001 – August 28, 2003 (per NHTSA)
Defect description
ON CERTAIN MOTOR HOMES, THE ELECTRIC POWER FOR THE ENTRY DOORSTEP "LAST OUT" FEATURE HAS NOT BEEN PROVIDED AND THE ENTRY DOORSTEP WILL NOT OPERATE IN "LAST OUT" MODE. THE "LAST OUT" IS A SAFETY FEATURE THAT CAUSES THE ENTRY DOORSTEP TO EXTEND ONE LAST TIME IF THE ENTRY DOORSTEP POWER SWITCH IS OFF AND THE VEHICLE IGNITION IS TURNED OFF.
Manufacturer remedy
DEALERS WILL INSPECT AND PROVIDE POWER SO THE ENTRY DOORSTEP "LAST OUT" FEATURE IS ACTIVE. OWNER NOTIFICATION BEGAN SEPTEMBER 10, 2003. OWNERS SHOULD CONTACT FLEETWOOD AT 1-800-322-8216.
Notes
FLEETWOOD RECALL NO. 30815.CUSTOMERS CAN ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4236).
Other Fleetwood Revolution model years
Check your 2003 Fleetwood Revolution VIN
Not every recall applies to every VIN in a given year. Enter the 17-character VIN from your Fleetwood Revolution at nhtsa.gov/recalls to see whether your specific vehicle has an unrepaired recall.
Check a Fleetwood VIN