NHTSA vehicle safety data
1995 Winnebago Brave Recalls & Complaints
The 1995 Winnebago Brave has 3 NHTSA recall campaigns and 3 owner complaints on file as of November 3, 2026. Recall repairs are usually free at an authorized Winnebago dealer.
NHTSA recall and complaint data for the 1995 Winnebago Brave. Recall data is refreshed daily from NHTSA.
1995 Winnebago Brave owner complaints
Owners have filed 3 complaints with NHTSA about the 1995 Winnebago Brave, describing incidents dated July 9, 1995 to September 5, 2009.
Most-cited components
- Engine 2 complaints
- Electrical System 1 complaint
- Power Train 1 complaint
- Service Brakes 1 complaint
- Steering 1 complaint
Of the 3 complaints on file, 1 reports a crash; across all 3 complaints, owners report 7 injuries (owner-reported, not verified by NHTSA).
Newest complaints
ODI #10576016 · Filed
VEHICLE COMPONENT DESIGN AND OPERATOR USAGE CONCERN: WHEN SHIFTING IN OR OUT OF LOW GEAR (AUTOMATIC TRANSMISSION W/ COLUMN SHIFT), DURING BEGINNING/COMPLETING A STEEP DESCENT, SHIFT LEVER SOMETIMES HITS THE IGNITION KEYS AND TURNS "OFF" THE IGNITION. THIS OCCURS, OCCASIONALLY, WHEN THE STEERING…
ODI #965972 · Filed
WHILE DRIVING, LOST STEERING CAPABILITY, WHEN PITMAN ARM BECAME LOOSE, CAUSING AN ACCIDENT. TT
ODI #484444 · Filed
TAIL PIPE EXTENDS FEW INCHES BEYOND BODYWORK AND IS EXPOSED TO GAS SPILLAGE DURING REFUELING.
WINNEBAGO/REFRIGERATOR C00LING UNIT FIRE
NHTSA #02V277005 · Equipment — Recreational Vehicle/Trailer · NHTSA notice
Reported December 10, 2002 · WINNEBAGO INDUSTRIES, INC.
Potentially affected: 1,531 vehicles
Vehicles built January 1, 1987 – June 30, 1995 (per NHTSA)
Defect description
CERTAIN MOTOR HOMES EQUIPPED WITH NORCOLD REFRIGERATOR COOLING UNITS MODEL NUMBERS 1200LR AND 1200RIM WITH SERIAL NUMBERS BETWEEN 700000 AND 1008700 . THESE REFRIGERATORS CAN EXPERIENCE LOW CYCLE FATIGUE FAILURE WHICH CAN LEAD TO THE LIQUID SOLUTION SLOWLY LEAKING FROM THE SEALED, PRESSURIZED COOLING UNIT THROUGH A SMALL CRACK.
Safety consequence
IF A LEAK OCCURS AND THE UNIT IS CONTINUALLY OPERATED, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.
Manufacturer remedy
NORCOLD WILL NOTIFY ITS CUSTOMERS AND PROVIDE A REPLACEMENT COOLING UNIT FREE OF CHARGE. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT NOROLD SERVICE AT 1-800-667-3005 OR WINNEBAGO AT 641-585-3535.
Notes
ALSO, CUSTOMERS CAN CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4326).
WINNEBAGO/SPARE TIRE CARRIER
NHTSA #97V012000 · Equipment — Mechanical — Carrier/Rack · NHTSA notice
Reported February 3, 1997 · WINNEBAGO INDUSTRIES, INC.
Potentially affected: 10,590 vehicles
Owners notified January 31, 1997 · Vehicles built July 11, 1988 – September 12, 1996 (per NHTSA)
Defect description
THE SPARE TIRE CARRIER HOIST COMPONENTS CAN BECOME LOOSE WHILE TRAVELING AND ALLOW THE SPARE TIRE TO MOVE FROM ITS STORED POSITION TO THE ROAD SURFACE.
Safety consequence
THE SPARE TIRE CAN CONTACT THE ROAD SURFACE INCREASING THE RISK OF A VEHICLE CRASH OR PROPERTY DAMAGE TO THE FOLLOWING VEHICLES.
Manufacturer remedy
DEALERS WILL ADD A PRIMARY SPARE TIRE SUPPORT BRACKET.
Notes
OWNER NOTIFICATION:OWNER NOTIFICATION IS EXPECTED TO BEGIN FEBRUARY 14, 1997. NOTE:OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT WINNEBAGO AT 1-515-582-6939.ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.
Electrical System — Wiring — Fuses and Circuit Breakers
Reported October 12, 1995 · WINNEBAGO INDUSTRIES, INC.
Potentially affected: 7,796 vehicles
Defect description
A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT.
Safety consequence
THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORTELSEWHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, ANDEVEN FIRE, WITHOUT WARNING.
Manufacturer remedy
DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED.
Notes
SYSTEM: ELECTRICAL; FUSE AND FUSE RECEPTICLE.VEHICLE DESCRIPTION: RECREATIONAL VEHICLES EQUIPPED WITH MAGNETEK POWERCONVERTERS WHICH USE A DORAN MANUACTURING FUSE PANEL (SEE DORAN CAMPAIGNNO. 95E016).NOTE: IF THE FUSE PANELS ARE NOT REPLACED FREE OF CHARGE WITHIN A REASONABLETIME, PLEASE CONTACT DORAN AT 1-800-681-5424. ALSO CONTACT THE NATIONALHIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.
Other Winnebago Brave model years
Check your 1995 Winnebago Brave VIN
Not every recall applies to every VIN in a given year. Enter the 17-character VIN from your Winnebago Brave at nhtsa.gov/recalls to see whether your specific vehicle has an unrepaired recall.
Check a Winnebago VIN