NHTSA vehicle safety data

1995 Winnebago Brave Recalls & Complaints

The 1995 Winnebago Brave has 3 NHTSA recall campaigns and 3 owner complaints on file as of November 3, 2026. Recall repairs are usually free at an authorized Winnebago dealer.

NHTSA recall and complaint data for the 1995 Winnebago Brave. Recall data is refreshed daily from NHTSA.

1995 Winnebago Brave owner complaints

Owners have filed 3 complaints with NHTSA about the 1995 Winnebago Brave, describing incidents dated July 9, 1995 to September 5, 2009.

Most-cited components

  • Engine 2 complaints
  • Electrical System 1 complaint
  • Power Train 1 complaint
  • Service Brakes 1 complaint
  • Steering 1 complaint

Of the 3 complaints on file, 1 reports a crash; across all 3 complaints, owners report 7 injuries (owner-reported, not verified by NHTSA).

Newest complaints

  • ODI #10576016 · Filed

    VEHICLE COMPONENT DESIGN AND OPERATOR USAGE CONCERN: WHEN SHIFTING IN OR OUT OF LOW GEAR (AUTOMATIC TRANSMISSION W/ COLUMN SHIFT), DURING BEGINNING/COMPLETING A STEEP DESCENT, SHIFT LEVER SOMETIMES HITS THE IGNITION KEYS AND TURNS "OFF" THE IGNITION. THIS OCCURS, OCCASIONALLY, WHEN THE STEERING…

  • ODI #965972 · Filed

    WHILE DRIVING, LOST STEERING CAPABILITY, WHEN PITMAN ARM BECAME LOOSE, CAUSING AN ACCIDENT. TT

  • ODI #484444 · Filed

    TAIL PIPE EXTENDS FEW INCHES BEYOND BODYWORK AND IS EXPOSED TO GAS SPILLAGE DURING REFUELING.

Read all 3 complaints

WINNEBAGO/REFRIGERATOR C00LING UNIT FIRE

NHTSA #02V277005 · Equipment — Recreational Vehicle/Trailer · NHTSA notice

Reported December 10, 2002 · WINNEBAGO INDUSTRIES, INC.

Potentially affected: 1,531 vehicles

Vehicles built January 1, 1987 – June 30, 1995 (per NHTSA)

Defect description

CERTAIN MOTOR HOMES EQUIPPED WITH NORCOLD REFRIGERATOR COOLING UNITS MODEL NUMBERS 1200LR AND 1200RIM WITH SERIAL NUMBERS BETWEEN 700000 AND 1008700 . THESE REFRIGERATORS CAN EXPERIENCE LOW CYCLE FATIGUE FAILURE WHICH CAN LEAD TO THE LIQUID SOLUTION SLOWLY LEAKING FROM THE SEALED, PRESSURIZED COOLING UNIT THROUGH A SMALL CRACK.

Safety consequence

IF A LEAK OCCURS AND THE UNIT IS CONTINUALLY OPERATED, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.

Manufacturer remedy

NORCOLD WILL NOTIFY ITS CUSTOMERS AND PROVIDE A REPLACEMENT COOLING UNIT FREE OF CHARGE. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT NOROLD SERVICE AT 1-800-667-3005 OR WINNEBAGO AT 641-585-3535.

Notes

ALSO, CUSTOMERS CAN CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4326).

WINNEBAGO/SPARE TIRE CARRIER

NHTSA #97V012000 · Equipment — Mechanical — Carrier/Rack · NHTSA notice

Reported February 3, 1997 · WINNEBAGO INDUSTRIES, INC.

Potentially affected: 10,590 vehicles

Owners notified January 31, 1997 · Vehicles built July 11, 1988 – September 12, 1996 (per NHTSA)

Defect description

THE SPARE TIRE CARRIER HOIST COMPONENTS CAN BECOME LOOSE WHILE TRAVELING AND ALLOW THE SPARE TIRE TO MOVE FROM ITS STORED POSITION TO THE ROAD SURFACE.

Safety consequence

THE SPARE TIRE CAN CONTACT THE ROAD SURFACE INCREASING THE RISK OF A VEHICLE CRASH OR PROPERTY DAMAGE TO THE FOLLOWING VEHICLES.

Manufacturer remedy

DEALERS WILL ADD A PRIMARY SPARE TIRE SUPPORT BRACKET.

Notes

OWNER NOTIFICATION:OWNER NOTIFICATION IS EXPECTED TO BEGIN FEBRUARY 14, 1997. NOTE:OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT WINNEBAGO AT 1-515-582-6939.ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.

Electrical System — Wiring — Fuses and Circuit Breakers

NHTSA #95E016005 · NHTSA notice

Reported October 12, 1995 · WINNEBAGO INDUSTRIES, INC.

Potentially affected: 7,796 vehicles

Defect description

A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT.

Safety consequence

THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORTELSEWHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, ANDEVEN FIRE, WITHOUT WARNING.

Manufacturer remedy

DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED.

Notes

SYSTEM: ELECTRICAL; FUSE AND FUSE RECEPTICLE.VEHICLE DESCRIPTION: RECREATIONAL VEHICLES EQUIPPED WITH MAGNETEK POWERCONVERTERS WHICH USE A DORAN MANUACTURING FUSE PANEL (SEE DORAN CAMPAIGNNO. 95E016).NOTE: IF THE FUSE PANELS ARE NOT REPLACED FREE OF CHARGE WITHIN A REASONABLETIME, PLEASE CONTACT DORAN AT 1-800-681-5424. ALSO CONTACT THE NATIONALHIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.

Other Winnebago Brave model years

Check your 1995 Winnebago Brave VIN

Not every recall applies to every VIN in a given year. Enter the 17-character VIN from your Winnebago Brave at nhtsa.gov/recalls to see whether your specific vehicle has an unrepaired recall.

Check a Winnebago VIN