2003 Gulf Stream Yellowstone Recalls & Complaints

The 2003 Gulf Stream Yellowstone has 5 NHTSA recall campaigns and 1 owner complaint on file as of November 3, 2026. Recall repairs are usually free at an authorized Gulf Stream dealer.

NHTSA recall and complaint data for the 2003 Gulf Stream Yellowstone. Recall data is refreshed daily from NHTSA.

2003 Gulf Stream Yellowstone owner complaints

Owners have filed 1 complaint with NHTSA about the 2003 Gulf Stream Yellowstone, describing incidents dated December 4, 2019.

Most-cited components

  • Trailer Hitches 1 complaint

The complaint on file reports a crash (owner-reported, not verified by NHTSA).

Newest complaints

  • ODI #11323179 · Filed

    TL* THE CONTACT OWNS A 2003 GULF STREAM YELLOWSTONE RV. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 06E033000 (TRAILER HITCHES) HOWEVER, THE PART TO DO THE RECALL REPAIR WAS NOT AVAILABLE. HIDDEN HITCH LOCATED AT 47912 HALYARD DR, SUITE. 100, PLYMOUTH, MI 48170, (800)632-3290, WAS…

Read the full complaint

ELECTRICAL WIRING

NHTSA #12V105000 · Electrical System — Wiring · NHTSA notice

Reported March 20, 2012 · GULF STREAM COACH, INC.

Potentially affected: 1,502 vehicles

Gulf Stream campaign 12WG-0105 · Owners notified April 4, 2012 · Vehicles built January 5, 2001 – March 14, 2005 (per NHTSA)

Defect description

GULF STREAM IS RECALLING CERTAIN MODEL YEAR 2001-2005 CLASS “A” AND “C” RECREATIONAL VEHICLES, BUILT ON FLOORPLANS 6316, 6317, 6330, 8325 AND 8328, DUE TO A SECTION OF UNSECURED WIRING. SEE THE ABOVE LIST FOR THE MODELS AFFECTED. THE WIRING WITHIN THE RACEWAY MAY NOT BE PROPERLY SECURED LEADING TO WEAR AND POTENTIAL HEAT DEVELOPMENT BETWEEN THE EXPOSED WIRING AND HEATED REFRIGERATOR COILS.

Safety consequence

THIS CONDITION COULD LEAD TO FAILURE OF THE 110 VOLT ELECTRICAL WIRING ROUTED TO THE MICROWAVE CABINET, INCREASING THE RISK OF FIRE, PERSONAL INJURY, OR PROPERTY DAMAGE.

Manufacturer remedy

GULF STREAM WILL NOTIFY OWNERS AND DEALERS WILL REPAIR THE VEHICLES, FREE OF CHARGE. THE SAFETY RECALL BEGAN ON APRIL 4, 2012. OWNERS MAY CONTACT GULF STREAM AT 1-800-482-6456.

Notes

GULF STREAM’S RECALL NUMBER IS 12WG-0105.OWNERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION’S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO HTTP://WWW.SAFERCAR.GOV.

REFRIGERATORS/POSSIBLE FIRE

NHTSA #10V584000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice

Reported November 22, 2010 · GULF STREAM COACH, INC.

Potentially affected: 1,328 vehicles

Owners notified March 23, 2011

Defect description

GULF STREAM IS RECALLING CERTAIN RECREATIONAL VEHICLES AND FIFTH WHEEL TRAILERS EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Safety consequence

THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Manufacturer remedy

GULF STREAM IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE RECALL BEGAN ON MARCH 23, 2011. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101 OR GULF STREAM AT 1-574-773-7761.

Notes

OWNERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO <A HREF=HTTP://WWW.SAFERCAR.GOV>HTTP://WWW.SAFERCAR.GOV</A> .

REFRIGERATOR FIRE/NORCOLD

NHTSA #09V382000 · Equipment · NHTSA notice

Reported October 1, 2009 · GULF STREAM COACH, INC.

Potentially affected: 242 vehicles

Owners notified October 20, 2009 · Vehicles built February 9, 2001 – March 25, 2003 (per NHTSA)

Defect description

GULF STREAM IS RECALLING CERTAIN MOTORHOMES EQUIPPED WITH NORCOLD MODEL 1200LR, 1200LRIM, AND 1201LRIM REFRIGERATORS WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK. IF A LEAK OCCURS AND THE REFRIGERATOR CONTINUES TO BE OPERATED AFTER SOLUTION CIRCULATION HAS CEASED THE HEAT SOURCE COULD GENERATE VERY HIGH TEMPERATURES. AT SUCH HIGH TEMPERATURES, THE COOLING UNIT COULD RUPTURE.

Safety consequence

IF A LEAK OCCURS AND THE UNIT CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.

Manufacturer remedy

GULF STREAM IS WORKING WITH NORCOLD AND THE VEHICLE'S REFRIGERATOR WILL BE REPAIRED FREE OF CHARGE. PLEASE ALSO SEE NORCOLD'S DEFECT NOTICE 09E-027. THE SAFETY RECALL BEGAN ON OCTOBER 20, 2009. OWNERS MAY CONTACT GULF STREAM AT 1-800-289-8787 OR NORCOLD'S RECALL CENTER AT 1-800-767-9101.

Notes

OWNERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO <A HREF=HTTP://WWW.SAFERCAR.GOV>HTTP://WWW.SAFERCAR.GOV</A> .

REFRIGERATOR/DOMETIC

NHTSA #08V411000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice

Reported August 15, 2008 · GULF STREAM COACH, INC.

Potentially affected: 26,847 vehicles

Owners notified October 31, 2008 · Vehicles built June 1, 2003 – October 31, 2006 (per NHTSA) · Recall influenced by NHTSA's Office of Defects Investigation

Defect description

GULF STREAM IS RECALLING 26,847 MY 2003-2006 RECREATIONAL VEHICLES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION. THE REFRIGERATOR MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.

Safety consequence

IF THIS SOLUTION IS EXPOSED TO AN IGNITION SOURCE UNDER CERTAIN SPECIFIC CIRCUMSTANCES, IT CAN RESULT IN A VEHICLE FIRE.

Manufacturer remedy

GULF STREAM IS WORKING WITH DOMETIC TO REPAIR THESE REFRIGERATORS (PLEASE SEE 08E032). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST THE OWNER IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR GULF STREAM AT 1-574-773-7761.

Notes

CUSTOMERS MAY CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY: 1-800-424-9153); OR GO TO HTTP://WWW.SAFERCAR.GOV.

REFRIGERATOR/DOMETIC

NHTSA #07V136000 · Equipment — Recreational Vehicle/Trailer · NHTSA notice

Reported March 20, 2007 · GULF STREAM COACH, INC.

Potentially affected: 38,767 vehicles

Owners notified June 28, 2007 · Vehicles built April 1, 1997 – August 31, 2003 (per NHTSA)

Defect description

CERTAIN MOTOR HOMES, FIFTH WHEEL AND TRAVEL TRAILERS EQUIPPED WITH A TWO-DOOR REFRIGERATOR, MANUFACTURED BY THE DOMETIC CORPORATION, MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.

Safety consequence

RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.

Manufacturer remedy

GULF STREAM WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST YOU IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. THE RECALL BEGAN ON JUNE 28, 2007. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR GULF STREAM AT 1-574-773-7761.

Notes

CUSTOMERS MAY CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY: 1-800-424-9153); OR GO TO HTTP://WWW.SAFERCAR.GOV.