NHTSA campaign 21V003000

Braun Ambulances Recall 21V-003: D-Ring Installed Too Close To Mounting Flange

NHTSA recall 21V003000 was reported by Braun Ambulances on January 8, 2021, with 61 vehicles potentially affected (per NHTSA). NHTSA's record lists the Crestline Coach CCL150 Type III and Crestline Coach CCL150 Type I for model years 2019–2021. Owners were notified on March 1, 2021, per NHTSA.

Updated daily from NHTSA's recall files

Is my vehicle included?

This page lists, by model year, the vehicles NHTSA's recall record names for campaign 21V003000 in the model years try.vin imports (1995 and later); NHTSA's own record can list more. A model year on the list doesn't mean every vehicle of that year is included, and some may already have been repaired.

To see whether a specific vehicle is included and still needs the repair, enter its VIN at nhtsa.gov/recalls.

Free VIN check: decode a VIN to see its year, make and model.

Key facts

NHTSA campaign
21V003000 (also written 21V-003 or 21V003)
Filed by
Braun Ambulances
Report received
Potentially affected
61 vehicles (per NHTSA)
Component
Seat Belts — Critical Fasteners
Owners notified

Repair completion: 100% (latest rate the manufacturer reported to NHTSA; dataset updated October 21, 2026)

NHTSA cautions against comparing completion rates across recalls or manufacturers. How try.vin reads them.

Vehicles listed for this recall

NHTSA's recall record lists these vehicles for recall 21V003000. try.vin imports model years 1995 and later, so NHTSA's own list can be longer. Model years with a try.vin recall page link to it. Build dates are NHTSA's range for a model year (per NHTSA); a vehicle built in that range is not necessarily included.

Crestline Coach

All Crestline Coach recalls

NHTSA's recall notice

As NHTSA's recall record states it for campaign 21V003000.

Defect description

Braun Ambulances (Braun) is recalling certain 2019 and 2021 Crestline CCL150 Type III E-Series and 2019-2020 Crestline CCL150 Type I F-Series and CCL150 Type III G-Series ambulances. Two of the eight fastening points of the seat belt system installed in the ambulance patient compartment side-facing CPR seating position on the street-side of the vehicle may be defective. Two of the threaded inserts used for the rearward retractor and shoulder belt D-ring are installed too close to a mounting flange resulting in improper crimping of the threaded insert.

Safety consequence

The improper crimping may result in partial or complete loss of effectiveness of the seat belt harness, increasing the risk of injury to the occupant in that seated position, in the event of a crash.

Manufacturer remedy

Braun will notify owners and dealers will inspect both seat belt anchor points and if no defect exists, no further action will be required. If the inspection shows the defect exists on one or both seat belt anchor points, your dealer will replace the defective insert(s) with nut plate(s) during the inspection, free of charge. The recall began on March 1, 2021. Owners may contact Braun Ambulances customer service at 1-877-344-9990.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

Sources

Official NHTSA notice for recall 21V003000